Function MP
No. Bit
A B C Input AE-6
Entry value
Compensation for reversal spikes
with digitally controlled driving
axes
X
Y
Z
IV
V
1960.0
1960.1
1960.2
1960.3
1960.4
-1.0000 to +1.0000 [mm] 0
0
0
0
0
Movement monitoring for position
and speed
(only for digitally controlled driving axes)
X
Y
Z
IV
V
1970.0
1970.1
1970.2
1970.3
1970.4
0 to 1 [mm]
Note: entry value 0 Ö monitoring inactive
0,5
0,5
0,5
0,5
0,5
Delayed shutdown of speed
controller in EMERGENCY STOP 1980

0 to 1.999 [s] 0