Function MP
No. Bit
A B C Input AE-6
Entry value
Axis correction:
Backlash compensation X
Y
Z
IV
V
710.0
710.1
710.2
710.3
710.4
-1.0000 to +1.0000 [mm] 0
0
0
0
0
Compensation of reversal spikes in
circular interpolation
magnitude of reversal spike
X
Y
Z
IV
V
711.0
711.1
711.2
711.3
711.4
0 to 1 [mm] 0
0
0
0
0
feed rate to compensate
the reversal spike
X
Y
Z
IV
V
712.0
712.1
712.2
712.3
712.4
0 to 1 [mm per CLP cycle time] 0
0
0
0
0
magnitude of reversal spike
(only effective with M05)
X
Y
Z
IV
V
715.0
715.1
715.2
715.3
715.4
08
08
08
08
08
0 to 1 [mm] 0
0
0
0
0
feed rate to compensate the reversal
spike (only effective with M05)
X
Y
Z
IV
V
716.0
716.1
716.2
716.3
716.4
08
08
08
08
08
0 to 1 [mm per CLP cycle time] 0
0
0
0
0
R H
1.0 TNC
415 B/425
Machine Parameters MP 710.0 - MP 716.4 03.01.95 5.2 5